BR-스테인리스 리액션 케틀

> 상품 > 스테인리스 리액션 케틀 > BR-스테인리스 리액션 케틀 >

BR-2000 High Pressure Reactor

This high-pressure reactor is ideally suitable for larger experimental runs. This high-pressure reactor is available in stainless steel 1.4571 (SUS 316LTI), Hastelloy C-22, or with PTFE lining on all sides.

Model: BR-2000

Order NO.:

1227

Specific parameters will be adjusted according to product upgrades, without notice.

Quotation Request

PRODUCT OVERVIEW

Description

The scope of delivery for the high-pressure reactors BR-2000 includes rupture disc, dip tube, valve and a tool for a proper opening and closing of the reactors. According to customer requests, the reactors can be manufactured with stainless steel 316 Ti (1.4571) or hatelloy
C-22 (2.4602). Pressure measurement is made analog and/or digital.
Due to an extensive range of accessories, individual reactor configurations can be made easily. Examples of accessories are:
* Different heating methods (integrated or via additional instrument)
* Various stirring concepts
* Sample holders
* A number of control units
The BR-2000 reactors can be used for volumes up to 2,230 ml and convince by an easy handling, which represents a high level of user friendliness. Amongst others, this can be traced back to the opening and closing tool. All reactor vessels can be equipped with PTFE
inserts.
The reactors are used for different types of synthesis, material tests and catalysts researches.
Depending on the users’ needs, two of the six ports (8 mm tube connection) can be used individually. When adding t-connections, the number of free ports can be enlarged.

Technical Specification

 

BR-2000

Material

SUS316Ti or HC

SUS316Ti + PTFE

Temperature max.

300℃

230℃

Pressure max.

200 bar

Reactor Vessel

Volume

approx. 2,230 ml

Inner Diameter

90 mm

Inner Height

352 mm

Weight

approx. 16 kg

TFMTM-PTFE Insert* (integrated)

Volume

-

approx. 1,880 ml

Inner Diameter

-

84 mm

Inner Height

-

340 mm

Armatures

Standard Armatures

Rupture Disc, Dip Tube, Valve, Tool

Pressure Measurement

analog and/or digital

Ports (total)

6

Ports (free)

2**

Type of connection

8 mm Tube Connection

Heating Systems (optional)

Electrical Heating mantle

CHM-2000

Julabo thermostat

CTM-2000

Heating Coil

Stirring

Overhead stirrer with magnetic clutch

WB20C and RV 100-SS

Stand

Electric lifting stand for BR-2000

* When using PTFE inserts the maximum allowable temperature is 230℃
* The number of free ports can be enlarged by the use of T-connections

skype
  • 연락처

  • WIGGENS GmbH
  • Wiescher Str. 11a, 42277 Wuppertal
  • Germany
  • Tel.: +49 202 373 29 58-0
  • E-mail: eusupport@wiggens.com

  • WIGGENS CHINA
  • Room 426, Hall A, Office Building M8, No. 1 Jiuxianqiao East Road, Chaoyang District, Beijing
  • Tel.: +86 400-809-2068
  • E-mail: info@wiggens.com

  • www.wiggens.com

회사 연락처 Statement Privacy Policy

Copyright © 2024 WIGGENS CO., LTD. All rights reserved.